Laboratory Equipements
NO. | Device name | Reference for examination | Properties | Made in |
1 | SEM+GOLD SPUTTERING | MRS-6 | is used to measure nano size structure and to characterize the surface topography of Nanomaterial’s with high resolving power up to 1nm Magnification:1x to 100,000x | USA |
2 | XRD | ASTM E1426 | is used to determine the crystal structure of solid materials by the interaction of x-ray with the atoms of crystalline solids which is normally distributed in regular arrangements Scanning radius: 185mm | Shimadzu / Japan |
3 | AFM | 80123-2D-AFM | is a very high-resolution type of scanning probe microscopy, with demonstrated resolution on the order of fractions of a nanometer, Resolution: AFM 0.26nm lateral, 0.1nm vertical | USA |
4 | ZETA POTENTIAL | EN 60825-1:2001 | Is used to measure the electrokinetic potentional in colliodal dispersions Standard Laser: 35 mW red diode laser, nominal 640 nm wavelength | USA |
5 | PARTICLE SIZE ANALYZER | ISO 13321 & ISO 22412 | Is used to determine the particle size of nanomaterials suspended in liquids. Standard Laser: 35 mW red diode laser, nominal 640 nm wavelength
| USA |
6 | GC | Depending on preparation method | The GC-2010 Plus enables reliable, high-precision trace analysis with high repeatability, utilizing detectors such as FID and FPD that feature best-in-class sensitivity | Shimadzu / Japan |
7 | Atomic Force Spectrophotometer | Depending on preparation method | Photometry section ·Measured wavelength : 185 to 900 nm ·Spectroscope : aberration correction type, Czerny-Turner mount ·Bandwidth : 0.2, 0.7, 0.7 L, 2.0 Lnm (automatic converted in 4 steps) ·Detector : photo multiplier (185.0 to 600.0 nm), semiconductor (600.1 to 900.0 nm) · Background correction : high-speed self-reversal, high-speed deuterium lamp ·Number of mounted lamps : 6 and 2 arbitrary lighted on the same time (another 1 for extra light) ·Lighting mode : EMISSION, NON-BGC, BGC-SR, BGC-D2 Date processing ·OS : AA Wizard (for device control character and date processing) Burner part ·Burner head : 10 cm (about 3.9″) slot made of titanium ·Nebulizer : Pt-Ir capillary, teflon orifice ·Power supply : AC 100, 120, 230 V 50/60 Hz External dimension : W 835 x D 545 x H 460 mm (about W 2.74 ft x D 1.79 ft x 1.51 ft) Weight : approx. 70 kg (about 154.5 lb) | Shimadzu / Japan |
8 | UV-Vis spectrum | ISO-17025 | UV/Visible Spectrophotometer is an accurate, reliable, and cost effective instrument designed for quality control, research, and teaching requirements. Wavelength Range: 190~1100nm | Taiwan |
9 | FTIR spectrum | ASTM E1421-99 | Fourier Transform Infrared (FTIR) Spectrophotometer: An analysis system that irradiates samples with infrared light, detects the transmitted or reflected light from the sample and uses “Fourier transform” mathematical processing to obtain spectra Measuring Wavenumber Range: 7800 cm-1 to 350 cm-1 | Shimadzu / Japan |
10 | Optical Microscopes | ASTM E 2218-02 | The microscope is used in research fields, such as biology, bacteriology, histology and pharmaceutical chemistry etc. Magnification: 4x to 1200x sample size: 140X160mm | Germany |
11 | Corrosion rate measuring device | ASTM G70-G72 | · Portable, Low Noise · Potential Range: ±2.000 V · CV Scan Rate: 1e-5 to 1e-10 V/sec | USA |
12 | Ultrasound examination device | GENERAL | Used for structural assessment and prediction of the mechanical properties and modulus of elasticity for construction materials. | Switzerland |
13 | Microhardness measuring device | ASTM E-92 | · Testing Force: 10g (0.098N)- 1000g (9.8N) · Min. Measuring Unit: 0.01μm · Hardness Value Rang: 1HV-4000HV/1HK-4000HK · Specimen Allowing Maximum Height: 85mm · Throat Depth: 120mm · Instrument size: 490×185×515mm(L×W×H) · Instrument weight: 45k | China |
14 | Compressibility testing device | ASTM A370 ASTM A321 | JYS-2000A digital display building materials compression testing machine is mainly used to brick, cement and concrete compression test: Max. capacity (KN): 2000 Measuring range: 4%-100% of FS | China |
15 | impact testing device | ISO 180 ASTM D256 | It is used to test or determine the anti- impact capacity of non-metal materials such as plastic Impact velocity: 3.8 m/s Pendulum energy: 0.5J 1J 2J 4J 5J | China |
16 | Hardness testing device | ASTM D2240 | Digital Micro Vickers Hardness Testers Test Forces: (0.098, 0.246, 0.49, 0.98, 1.96, 2.94, 4.90, 9.80) N | China |
17 | Tensile testing device | D 638 | PL | China |
18 | OSCILLOSCOPE | Depending on research | Max real time sampling rate: 400Msps Max equivalent sampling rate: 10Gsps Bandwidth: 25MHz Input impedance: 1MΩ||18pF | Germany |
19 | HALL EFFECT SETUP | Depending on preparation method | Range: 0-200mV (Resolutio 100μV) Accuracy: ±0.1% of reading ±1 digit Impedance: 1Mohm | India |
20 | KETHELY SOURCE METER | SCPI GPIB | Built-in sweeps for I/V, I/R, V/I, and V/R characterization Ohms Range <0.2 Ω to >200 Ω Current Range ±10 pA to ±1.05 A Voltage Range ±1 µV to ±210 V | Kethely/ USA |
21 | MULTIAMATE | Depending on research | V DC Ranges: 100 mV to 1000 V V AC Ranges: 8845A: 100 mV to 750 V Resistance Ranges: 8845A: 100 Ω to 100 MΩ A DC Ranges: 100 μA to 10 A A AC Ranges: 10 mA to 10 A Capacitance Ranges 1 nF to 0.1 F Temperature Ranges: -200 °C to +600 ° | USA |